Static Eliminators for printing presses
Ionix Static Eliminators for eliminating static in the feeder of printing presses, screen presses, die cutters, laminators and other sheet-feeding machines feeding paper or plastic!
Static on the paper or plastic interior surfaces of the sheets in the machine feeder cause sheets to be electrically attracted to each other and resist sheet separation by the feeder. This causes either feeder jams or slower running speeds.
Installing Ionix Static Eliminators in your feeder air line makes your feeder air eliminate those interior surface charges during sheet separation by directing Ionix static eliminating air in between the sheets in the pile. The result is the internal static between the sheets in the pile is dissipated, resulting in no feeder jams and consistently increased running speeds on your machines.
Click on Ionix
Static Eliminators for Printing Presses and Folders for a
brochure (pdf).
Fast delivery
We manufacture all Ionix Static Eliminators at our location and can
generally ship to you next-day air if necessary.
Ionix Static Eliminators are simple to install
You can install them yourself! Ionix is installed on the main
blow/pressure line going from the feeder pump to the feeder. If your
can cut a hose, you can install Ionix!
For optimum results, all the air coming from the feeder pump should go through the Ionix Static Eliminator.
Identify that hose and measure the inside diameter of the hose. Cut that hose and push the hose ends over the tapered nipple ends of the Ionix Static Eliminator. Installation is complete. No electrical wiring is necessary. Ionix does not contain nuclear material.
If your machine has more than one feeder pump - such as a side blower pump - that pump must also be equipped with Ionix.
Click on Ionix Static Eliminator GA200-GA300-GA400 Instructions and Installation for instructions and installation (pdf.)
Sizing Ionix Static Eliminator for sheet-fed printing presses, die cutters and other sheet-feeding machines feeding paper
Ionix for presses are sized based upon:
- the maximum sheet size of the press and
- the inside diameter of the main blower air hose.
Therefore, in order to install Ionix on a sheet-feeding press you must have this information.
For sheet-feeding machines up to 22" (550MM) x 34"
(850MM) sheet size:
(Click on the underlined model to be directed to our secure Yahoo
store for pricing and to order)
for 1/2" (10MM) inside diameter feeder air hose:
Ionix
Model 200-2
for 3/4" (20MM) inside diameter feeder air hose:
Ionix
Model 200-3
for 1" (25MM) inside diameter feeder air hose:
Ionix
Model 200-4
for 1 1/4" (30MM) inside diameter feeder air hose:
Ionix
Model 200-5
for 1 1/2" (40MM) inside diameter feeder air hose:
Ionix
Model 400-6
for 1 3/4" (45MM) inside diameter feeder air hose:
Ionix
Model 400-7
for 2" (50MM) inside diameter feeder air hose:
Ionix
Model 400-8
For sheet-feeding machines over 22" (550MM) up to 26"
(650MM) x over 34" (850MM) up to 40" (1000MM) sheet size:
(Click on the underlined model to be directed to our secure Yahoo
store for pricing and to order)
for 1/2" (10MM) inside diameter feeder air hose:
Ionix
Model 300-2
for 3/4" (20MM) inside diameter feeder air hose:
Ionix
Model 300-3
for 1" (25MM) inside diameter feeder air hose:
Ionix
Model 300-4
for 1 1/4" (30MM) inside diameter feeder air hose:
Ionix
Model 300-5
for 1 1/2" (40MM) inside diameter feeder air hose:
Ionix
Model 400-6
for 1 3/4" (45MM) inside diameter feeder air hose:
Ionix
Model 400-7
for 2" (50MM) inside diameter feeder air hose:
Ionix
Model 400-8
Sizing Ionix Static Eliminators for feeding plastic or
synthetic sheets
For sheet-fed presses or machines feeding plastic or synthetic
sheets, install TWO of the appropriate size Ionix units for your
press in series (one Ionix after another separated by a short
section of hose).
For presses other than sheet-fed presses, sheeters or sheet-fed
presses greater than 26" x 40", please contact Ionix at
info@ionixtechnologies.com for sizing.
Static on printing press feeder boards resulting in
mis-register at head stops
Sometimes press operators will experience paper that will separate
and feed but the sheets will not uniformly feed down the feeder
board. Either sheets will not jog to the head stops or will not be
pulled by the side guide. This particular static problem is caused
by the friction of the feeder tapes moving over the surface of the
feeder board. The feeder tapes have a static charge on them which
attracts the paper to it while going down the feeder board.
To eliminate feeder board static, Ionix air must be blown between the bottom of the paper going down the feeder board and the top of the feeder board. Since virtually all machines do not have air delivery to these points, it is necessary to fabricate an air delivery system for each particular machine. Please contact Ionix and we will help you install an appropriate air delivery system for your machine.
Ionix Static Eliminators in offset spray powder units
improve powder laydown resulting in less powder use
Ionix installation in spray powder systems results in less powder
usage and more even spreading of powder.
Since offset powder is an electrical insulator, when the air pump blows into the offset spray powder, static is generated on the powder by the friction of the moving powder. The static charge on the powder causes the powder to stick together. Therefore, you get excessive powder usage and uneven powder application.
When you install an Ionix in the air line going from the pump to the spray powder unit, the offset spray powder system is static free. The Ionix treated air which enters the spray powder system eliminates any static present in the powder and prevents its buildup. Less powder is needed since the powder lays down thinner and broader. You will also have less powder buildup on your presses.
Install the Ionix in the pressure air hose going from the compressor to the spray powder unit.
For spray powder units in presses up to 22" (550MM) x 36"
(850MM)
(Click on the underlined model to be directed to our secure Yahoo
store for pricing and to order)
for 1/2" (10MM) inside diameter spray powder air hose:
Ionix
Model 200-2
for 3/4" (20MM) inside diameter spray powder air hose:
Ionix
Model 200-3
for 1" (25MM) inside diameter spray powder air hose:
Ionix
Model 200-4
(Click on the underlined model to be directed to our secure Yahoo
store to order)
For spray powder units in presses over 22" (550MM) up to 26"
(650MM) and over 36" (850MM) up to 40" (1000MM)
(Click on the underlined model to be directed to our secure Yahoo store for pricing and to order)
for 1/2" (10MM) inside diameter spray powder air hose:
Ionix
Model 300-2
for 3/4" (20MM) inside diameter spray powder air hose:
Ionix
Model 300-3
for 1" (25MM) inside diameter spray powder air hose:
Ionix
Model 300-4
(Click on the underlined model to be directed to our secure Yahoo
store to order)
Static in press deliveries
Very few presses have an issue with static causing delivery problems
in a sheet fed press. However, since there is no air handling system
in the delivery of sheet fed presses, Ionix cannot be used to
eliminate static delivery problems in sheet fed presses if it
occurs.
Remember that static eliminators are only effective in eliminating static at the point they are installed. Static eliminators are not static preventers. If you do have static in your delivery, installing a static eliminator in your feeder will not solve the static problem in the delivery. Contact Ionix if you are having difficulties with static in press deliveries and we will attempt to help you solve the problem.
Static in web press sheeters
Generally most static issues in web presses occur in the forming
cone or at the sheeter cutoff. Ionix has been successfully used in
web presses. Please contact Ionix for more details.
30 day satisfaction guarantee!
Use Ionix for 30 days. If you're not completely satisfied with your
Ionix Static Eliminator, you can return it IN ANY CONDITION for a
full and complete refund. Our goal is to solve your static problem
to your satisfaction. We warrant our product to be free of defects
for 6 months after installation. Replacement is recommended after
one year of actual use.
Questions?
Call 800-246-1784. You can get more information at our home page.
www.IonixTechnologies.com
Explanation of Ionix Static Eliminators in sheet feeders
Static on the surfaces of paper causes the sheets to be electrically
(not magnetically) attracted. The sheets are attracted because there
are opposing charges on each sheet. One sheet has a positive charge
and the facing side has a negative charge. Opposing static charges
will neutralize each other if they are allowed to come in electrical
contact with each other. However, in the paper stack in the feeder,
while to the naked eye it appears the sheets are touching, in
reality there is a thin layer of air insulating the sheets
preventing the opposing charges from conducting to one another.
When installed in the main feeder blast/pressure air line, the feeder pump forces air through Ionix. Air enters the Ionix acting like an electrical insulator and exits our unit acting like an electrical conductor (like copper wire). When the feeder blows into the feeder, the air that was originally in the paper pile acting as an electrical insulator is blown out and replaced with Ionix air acting like an electrical conductor. The charges on the interior paper surfaces that were before electrically isolated from each other by the air are now able to conduct through the Ionix electrically conductive air. The opposing charges on the paper surfaces conduct to each other through the Ionix air and ground each other out.
Why Ionix Static Eliminators are superior to electronic
ionizers in sheet feeders
Electronic ionizers create a stream of charged air molecules. It
produces a rapid succession of a pulse of negatively charged air and
then a pulse of positively charged air. That air is directed into
the paper stack. When a blast of charged air meets an opposing
charge, the ionized air and paper static charges neutralize each
other. At that point, the air has no more ability to neutralize a
charge because its charge was used to eliminate an opposing charge.
The ionized air is consumed in the process of eliminating the
static. Also, since opposing charges are attracted to one another
and will neutralize each other, an ionization air stream will
neutralize ITSELF within about 6-12” inches. Therefore, the
effective range for ionization is only about 2” into a stack of
paper before it recombines on itself.
Ionix has neither of these drawbacks. Since Ionix makes the air
electrically conductive, it is not consumed in the process of
neutralizing static. Ionix treated air is as effective at the rear
of the sheet as it is in the front. The only thing that diminishes
the performance of the Ionix treated air is when the ambient air
mixes in with the treated Ionix air. Secondly, since Ionix does not
ionize the air, it does not neutralize itself like an ionizer. There
is no recombinant (or neutralizing itself) effect like there is with
ionized air.
When the compressor air goes through the Ionix, the feeder mechanism
blows out the air between the paper sheets which is acting like an
electrical insulator and replaces it with Ionix air that acts like
an electrical conductor which discharges the static on the interior
surfaces of the paper. This eliminates the static attraction within
the paper in the feeder.
Ionix Static Eliminators are made in the USA with 100%
USA made components.
How to Order
Call Ionix at 800-246-1784
to order by phone
Go to our secure Yahoo!
hosted online store www.TheIonixStore.com